Hand Arm Vibration Syndrome is not a new problem. It has been recognised as an occupational disease for decades, and legislation has been in place since 2005 to protect workers. Yet it still causes tens of thousands of lost working days every year in the UK, because the early symptoms are subtle, the progression is slow, and many employers don't measure exposure until they're required to.

What is HAVS?

Hand Arm Vibration Syndrome (HAVS) is a collective term for the disorders caused by long-term exposure to vibration transmitted through the hands. The vibration comes from hand-held powered tools, grinders, drills, impact wrenches, chisels, needle scalers, percussive tools, sanders and similar equipment.

HAVS affects three systems:

  • Vascular, blood vessels in the fingers and hands. Cold, white fingers (Vibration White Finger) are the most recognisable symptom.
  • Neurological, tingling, numbness, loss of sensation and dexterity. Operators describe not being able to feel tools or small objects.
  • Musculoskeletal, weakness and pain in the hands, wrists and arms.

The condition is progressive. Early symptoms, tingling and numbness in the fingertips, sensitivity to cold, are easily dismissed. Without intervention, they worsen. Late-stage HAVS causes permanent numbness, inability to handle small objects, and in severe cases, Vibration White Finger triggered by cold air, not just cold water. It is not reversible.

Who is at risk?

Around 5 million workers in the UK use hand-held or hand-guided power tools. Around 2 million of those are exposed to vibration levels that could cause ill-health. The highest-risk industries are:

  • Construction, particularly breakers, hammers and chisels
  • Engineering and manufacturing, grinders, sanders, impact wrenches
  • Forestry, chainsaws
  • Mines and quarries
  • Road and ground maintenance
  • Manufacturing of concrete products and vehicles

The risk is determined by exposure, the vibration level of the tool and the time it's used. A low-vibration tool used for most of a shift can produce more exposure than a high-vibration tool used for a few minutes.

The regulations

The Control of Vibration at Work Regulations 2005 set legally binding daily exposure limits:

  • Exposure Action Value (EAV): 2.5 m/s² A(8), at this level, employers must introduce controls to reduce exposure further. Risk assessment and health surveillance are required.
  • Exposure Limit Value (ELV): 5.0 m/s² A(8), this must not be exceeded under any circumstances. It is a legal maximum, not a target.

A(8) is a time-weighted daily dose, it combines the vibration magnitude of each tool with the trigger time in a working day. A tool vibrating at 5 m/s² used for 2.5 hours produces an A(8) of 2.5 m/s², the action value. The same tool used for 10 hours would exceed the exposure limit value fourfold.

The problem with manufacturer data

Every pneumatic and electric tool sold in Europe must carry a declared vibration value, typically the free-running or lightly loaded vibration level measured on a test rig under ideal conditions. This is the starting point for exposure estimation.

It is not the endpoint. Real-world vibration levels are consistently higher than declared values. In practice, we measure levels two to three times higher on working production tools than the same model's declared value, sometimes more, particularly on worn tools or where grip force is high. An exposure assessment based on manufacturer data alone understates risk.

What employers must do

Under the regulations, employers must:

  • Assess the risk, identify which tools and tasks involve vibration exposure and estimate or measure the likely exposure level
  • Reduce exposure, where the EAV is likely to be exceeded, introduce controls: lower-vibration tools, reduced trigger times, job rotation, anti-vibration gloves, maintenance programmes
  • Provide health surveillance, for workers regularly exposed above the EAV, regular checks for early symptoms are a legal requirement
  • Inform and train workers, employees must know the risks, the symptoms and what to do if they notice early signs
  • Review and update, when tools, tasks or working patterns change, the assessment must be updated

On-site HAV testing

The most reliable way to assess real exposure is to measure it, with calibrated equipment, on your actual production tools, used by your operators in real conditions. That's what we do. Our engineers visit your site, mount tri-axial accelerometers at the tool grips, take repeated readings during actual use, and calculate A(8) values for each tool in the assessment.

The results often surprise people. Worn tools, poor condition, high grip force, all increase vibration levels significantly above the new-tool declared value. On-site testing reveals the actual risk; brochure values conceal it.

Every assessment produces: a per-tool report with measured values and trigger-time limits, an operator exposure spreadsheet, an HSE-ready management summary, and an action plan for any tools that need attention.

If you'd like to book an on-site HAV survey, contact us or call 01926 857193. We cover mainland UK.