The Control of Vibration at Work Regulations 2005 haven't changed, but the HSE's supporting guidance has been updated to reflect how real-world exposure is assessed, and inspectors are now asking harder questions.
What's changed in the guidance?
The main update concerns mixed-tool exposure calculations. Where an operator uses more than one vibrating tool during a shift, the combined A(8) must be calculated using the root-sum-of-squares method, not simply by adding exposure times. Many compliance spreadsheets in circulation still use the simpler (and less accurate) linear addition method.
The HSE has also clarified that manufacturer-quoted vibration values must not be used as-is in exposure calculations without adjustment for real-world conditions. The guidance now explicitly recommends that values be measured on your actual production line, in the hands of your operators, using calibrated equipment.
What this means in practice
If your HAV assessment relies solely on manufacturer datasheets, it almost certainly understates exposure. We've seen real-world measurements two to three times higher than the declared value, particularly on older or worn tools.
For companies already running annual HAV surveys with measured values, the update changes little. For those relying on estimates, now is the time to act before an inspection catches it.
What to do now
- Audit your current assessment method, linear addition or RSS?
- Check that your trigger-time records are up to date for each operator role
- If you're using manufacturer values, book a measured survey before Q3
- Ensure your assessment covers all vibrating tools, not just power tools (battery tools count)
If you'd like us to review your current records or book a measured survey, get in touch.